300 T/H Full-auto Biochemistry Analyzer
Application
Our biochemistry analyzers are multi-functional. Many test items can be done by our biochemistry analyzers. Following are test details:
1. Liver Functions Test: ALT, AST, TP, ALB, TBIL, DBIL, ALP, CHE, TBA, PA, A/G
2. Renal Functions Test: Urea, Cr, TCO2, UA
3. Lipids: CHOL, TG, HDL-C, LDL-C, Apo A1, Apo B, AMY, LIP, LP(a)
4. Myocardial Enzymes: LD, CK, CK-Mb
5. Ion: K+, Na+, Cl-, Ca++, Mg++, P
6. Other Items: GLU, Fe, GRP, IgG, IgA, IgM, G3, G4
Specification of Auto Biochemistry Analyzer YJ-300:
Model | YJ-300 |
|
Throughput |
Constant 300/h |
|
Theory |
Absorption spectrometry, transmission turbidimetry |
|
Methodology |
End-point \Fixed-time\Kinetic\Ion selective electrode |
|
Test according set up, random access |
Reaction plate |
Contain 81 reaction cuvettes |
Maximum reaction time |
15 minutes |
|
Minimum reaction volume |
150 ul |
|
Material of cuvettes |
Special UV-transparent optical glass |
|
Cuvettes use |
Automatically cuvettes washing |
|
Optical Unit |
Light Source |
Halogen-tungsten lamp |
Photometer |
Reversed optics |
|
Wavelength |
340nm-900nm wavelength option |
|
Absorption |
0-4 Abs |
|
Reagent Unit |
Reagent plate |
80 reagent positions ,support for single and double reagent, reagent completely open |
Reagent storage temperature |
2~10 degree |
|
Reagent bottle |
15ml, 20ml, 30ml, 50ml or 70ml ,dead volume is less than 1.0 ml |
|
Reagent volume |
20-500 ul, step by 1.0 ul |
|
Reagent/Sample Probe |
Automatically checked ;Patent technology liquid level detection;Collision protection probe cleaning:Automatic washing for both inside and outside. |
|
Sample Unit |
Sample plate |
80 sample positions |
Sample type |
Human (animal) serum \plasma\urine etc. |
|
Samples cup |
Support one-off micro cups |
|
Sample volume |
2-100 ul, step by 0.1 ul |
|
Sample/reagent probe |
Automatically checked ;Patent technology liquid level detection;Collision protection probe cleaning:Automatic washing for both inside and outside. |
|
Temperature control Unit |
Heating method |
Direct thermal solid thermostat closed |
Temperature equilibrium time |
<3 minutes |
|
Reaction temperature |
37 ±0.1 degree |
|
Temperature fluctuation |
±0.1 degree |
|
Operation Unit |
Software |
WindowsXP \2000 |
Database |
SQL Server |
|
Data Storage |
Automatic store & copy; No time and volume limit; Lifetime preservation |
|
Print format |
Can be set up, offer several standard format |
|
Calibration mode |
Linear curve type: Single-point linear, two-point linear and multi-point linear none linear; Curve type: Logistic-Log 4P,Logistic-Log5p,Spline,index automatically use best calibration curve and standard |
|
Quality control methods : |
Real time, within day & between day |
|
Quality control diagram |
L-J \cumulative\twin plot |
|
Status display |
Real time monitoring of reagent residual volume .Running status of reagent tray, samples tray |
|
Adjustment |
Dynamic and real time display of running status; Intelligent carry over settings to adjust test sequence; original reaction data record; Detail profile of alert messages |
|
Setting |
Operation permission setting, Item setting, cross pollution setting, cuvette blank setting |
|
Others |
Water consumption : < 6L/h |
Power Supply :AC 220V±22V 50Hz±1Hz |
Frequency :Maximum 600VA |
Dimension :782mm×581mm×545mm |
|
Net Weight : 60kg |
Accessory :Software |
Packing & Delivery
1-2 weeks for equipments.
7-20 working days for furniture and consumables
Customer can choose pick up or carry by poweam experienced braker by sea,by air or by dhl,tnt etc courier
Wooden pallet or solid cartons wrap with PVC film.Please reference picture below:
After-sales Service
All products of our company have a warranty of 12 months. We have special engineer for after-sales service. If any questions during the use, feel free to tell us by email, fax or telephone at any time, we will do our best to support you to keep your market reputation.
RFQ:
1.What is time of delivery?
Since our products are produced according to each specific order, the delivery period will be 15 days after confirmation of order. If it is small or sample order, please do check with us about whether we have ready goods in stock to make delivery as soon as possible.
2.What about quality assurance?
We offer one year warranty period beginning from the time of shipment for medical equipment, Per minor problems, we can provide free spare parts for replacements, Per serious problems, we can make replacement of free charge.
3.What is payment terms?
T/T in advance, Western Union.
4.Which shipping company usually using?
MAERSK-LINE, PIL, COSCO, SAFMARINE, MARUBA, APL, CMA, CSAV, K-LINE, MSC, NYK, AND DHL, EMS, TNT, UPS FOR COURIER, buyer's option will be our priority. We will give suggestion according to the schedule and services.
http://www.forermedchina.com/